Login | Register
產(chǎn)品中心
Home > Products > Self-priming pumps > ZXF Fluoroplastic Self-Priming Pump

ZXF Fluoroplastic Self-Priming Pump

    ZXF Fluoroplastic Self-Priming Pump

    The ZXF Fluoroplastic Self-Priming Pump is a premium corrosion-resistant pump designed for industrial, chemical, pharmaceutical, and municipal applications. Engineered with advanced fluoroplastic linings and robust self-priming technology, this pump delivers reliable and leak-free operation, even under challenging conditions involving corrosive, abrasive, or viscous liquids.
  • Share:
  • Contact us Inquiry
  • WhatsApp:13852624478

Product Introduction

The ZXF Fluoroplastic Self-Priming Pump is a premium corrosion-resistant pump designed for industrial, chemical, pharmaceutical, and municipal applications. Engineered with advanced fluoroplastic linings and robust self-priming technology, this pump delivers reliable and leak-free operation, even under challenging conditions involving corrosive, abrasive, or viscous liquids.

The ZXF pump is ideal for continuous or intermittent operations, providing efficient fluid transfer without the need for auxiliary priming devices. Its fluoroplastic materials, including PTFE, PFA, or FEP linings, ensure maximum chemical resistance, making it suitable for strong acids, alkalis, organic solvents, and aggressive chemical solutions.

Applications of the ZXF pump span chemical processing, pharmaceuticals, food and beverage industries, water and wastewater treatment, and industrial fluid circulation. With options for magnetic drive or mechanical seal configurations, the pump ensures complete leak-free operation, protecting both the environment and personnel.

The ZXF Fluoroplastic Self-Priming Pump guarantees quality, safety, and long-term operational reliability. Optional features include VFD (Variable Frequency Drive) compatibility, PLC/SCADA integration, thermal sensors, and automation-ready configurations, offering enhanced precision and energy efficiency.

u=1523736086,2532085514&fm=199&app=68&f=JPEG.jpg

Key Features

  1. Fluoroplastic Lining

    • Offers exceptional chemical resistance against acids, alkalis, and solvents.

    • Protects the pump against corrosion, erosion, and chemical attack, extending service life.

  2. Self-Priming Capability

    • Can prime itself automatically, even with low suction fluid levels or intermittent supply.

    • Eliminates the need for external priming devices, reducing downtime.

  3. Leak-Free Operation

    • Magnetic drive or mechanically sealed designs ensure environmentally safe, leak-free fluid transfer.

  4. High Efficiency and Wide Range

    • Flow rates: 1–1200 m3/h depending on pump size.

    • Maximum head: up to 90 meters.

    • Operating temperatures: -20°C to +120°C, depending on materials.

  5. Corrosion and Abrasion Resistance

    • Fluoroplastic linings protect against strong chemicals and abrasive slurries.

    • Suitable for industrial fluids, chemical solutions, and hazardous liquids.

  6. Automation Ready

    • Compatible with VFD, PLC, and SCADA systems for precise flow and pressure control.

    • Enables remote monitoring, automation, and energy-efficient operation.

  7. Durability and Low Maintenance

    • Reduced moving parts and modular design facilitate easy inspection and replacement.

    • Ensures long operational life with minimal maintenance costs.

  8. Wide Applications

    • Ideal for chemical, pharmaceutical, food-grade, and industrial fluids.


Technical Specifications (Product Parameters)

ParameterSpecification Range

Pump Type

Fluoroplastic Self-Priming Pump

Flow Rate

1 – 1200 m3/h

Head

Up to 90 meters

Pressure

Up to 16 bar depending on model

Operating Temperature

-20°C to +120°C depending on fluid and lining material

Material of Construction

Fluoroplastic (PTFE, PFA, FEP) linings, stainless steel, alloy

Impeller Type

Open or closed impeller

Shaft Material

Stainless steel or corrosion-resistant alloy

Seal Type

Magnetic drive or mechanical seal

Motor Type

TEFC electric motor or submersible motor

Cable Type

Chemical-resistant, insulated cable

Drive Options

Electric motor, VFD compatible

Installation Type

Horizontal self-priming

Noise Level

<75 dB(A) depending on model


Applications of ZXF Fluoroplastic Self-Priming Pump

1. Chemical Industry

  • Transfers strong acids, alkalis, organic solvents, and hazardous liquids.

  • Ideal for chemical reactors, storage tanks, and circulation systems.

2. Pharmaceutical Industry

  • Handles pharmaceutical liquids, sterile solutions, and sensitive compounds.

  • Compatible with CIP (Clean-In-Place) systems and high-purity fluid handling.

3. Food and Beverage Industry

  • Pumps food-grade liquids, syrups, oils, and beverages safely.

  • Ensures leak-free, contamination-free operation.

4. Water and Wastewater Treatment

  • Efficiently handles water, reclaimed water, and wastewater containing chemical additives.

  • Fluoroplastic lining prevents corrosion and chemical damage.

5. Industrial Fluid Transfer

  • Suitable for cooling liquids, chemical circulation, and industrial process fluids.

  • Provides stable flow and pressure with minimal maintenance.

6. Hazardous and Toxic Fluids

  • Safely transfers toxic, flammable, or environmentally sensitive liquids.

  • Leak-free design ensures safe operation in hazardous environments.

7. Laboratory and Pilot Plants

  • Ideal for small-scale chemical, pharmaceutical, and food operations.

  • Integrates with automation, monitoring, and precise flow control systems.

8. Remote or Unmanned Installations

  • Self-priming functionality allows operation without manual priming, suitable for unmanned pumping stations.


Operating Instructions

Pre-Start Checks

  • Verify pump installation, alignment, electrical connections, and piping.

  • Inspect impeller, bearings, shaft, and fluoroplastic lining integrity.

  • Ensure fluid compatibility with pump materials.

Start-Up Procedure

  1. Fill suction line with fluid if needed to aid initial priming.

  2. Power on the pump; automatic self-priming cycle will initiate.

  3. Monitor flow, pressure, temperature, and vibration.

  4. Adjust VFD or automation controls to achieve desired flow and pressure.

Normal Operation

  • Operate within rated flow, head, and temperature limits.

  • Periodically inspect impeller, casing, and motor.

  • Monitor vibration, noise, and performance parameters.

Shutdown Procedure

  • Gradually reduce flow before stopping the motor.

  • Drain fluids from suction and discharge lines if required.

  • Inspect and clean pump components after use.


Maintenance Guidelines

  1. Routine Inspection

    • Monitor vibration, noise, and alignment.

    • Inspect impellers, casing, fluoroplastic lining, and bearings.

  2. Fluoroplastic Lining Maintenance

    • Inspect for cracks, wear, or chemical degradation.

    • Replace lining if damaged to maintain chemical resistance.

  3. Motor and Electrical Maintenance

    • Monitor temperature, insulation, and bearing condition.

    • Lubricate bearings per manufacturer’s instructions.

  4. Seal and Coupling Maintenance

    • Inspect magnetic drive or mechanical seal alignment and integrity.

    • Replace worn or damaged seals promptly.

  5. Scheduled Overhaul

    • Every 12–18 months, depending on fluid type and operational hours.

    • Inspect and replace internal components if necessary.


Common Problems and Solutions

ProblemPossible CauseSolution

Pump fails to prime

Air in suction line or low fluid

Ensure suction line is filled or increase fluid level

Flow rate below specification

Impeller blockage or wear

Clean or replace impeller

Excessive vibration or noise

Misalignment or bearing wear

Check alignment, replace bearings

Leakage

Damaged mechanical seal or misalignment

Inspect and realign or replace seals

Motor overheating

Overload or insufficient cooling

Verify motor rating and thermal protection

Fluoroplastic lining damage

Chemical incompatibility or abrasion

Replace lining with compatible material

Automatic priming failure

Valve blockage or malfunction

Clean or replace priming system components


Advantages of ZXF Fluoroplastic Self-Priming Pump

  1. Fluoroplastic Chemical Resistance – Handles strong acids, alkalis, solvents, and abrasive fluids.

  2. Automatic Self-Priming – Operates reliably under low suction conditions.

  3. Leak-Free Design – Magnetic or mechanical sealing ensures environmental safety.

  4. High Efficiency – Optimized hydraulics reduce energy consumption.

  5. Automation Ready – VFD, PLC, and SCADA compatible.

  6. Low Maintenance – Fewer moving parts reduce operational downtime.

  7. Versatile Applications – Suitable for chemical, pharmaceutical, food, municipal, and industrial fluids.

  8. Certified Quality – ISO, CE, and API certified for reliability and safety.


The ZXF Fluoroplastic Self-Priming Pump is a robust, corrosion-resistant, and highly efficient pump designed for chemical, pharmaceutical, food, municipal, and industrial fluid applications. Its fluoroplastic lining, automatic self-priming functionality, leak-free design, and automation readiness ensure reliable, safe, and environmentally friendly operation, making it ideal for continuous and demanding industrial environments.

ONLINE MESSAGE

Please fill in a valid email address
Captcha Can not be empty

RELATED PRODUCTS

No search results found!

This website uses cookies to ensure you get the best experience on our website.

Accept Reject
永宁县| 新竹县| 榕江县| 漯河市| 湟中县| 杭锦旗| 海兴县| 开远市| 济南市| 康马县| 饶河县| 海淀区| 永丰县| 云安县| 来宾市| 湘阴县| 宜昌市| 长乐市| 饶平县| 宜阳县| 苏尼特右旗| 阳朔县| 依安县| 石林| 晋中市| 陇南市| 通化市| 墨竹工卡县| 双柏县| 灵寿县| 海盐县| 大理市| 扶绥县| 涪陵区| 万源市| 通江县| 巴东县| 大丰市| 大城县| 梧州市| 庆城县|