Login | Register
產(chǎn)品中心
Home > Products > Self-priming pumps > CZF Magnetic Self-Priming Pump

CZF Magnetic Self-Priming Pump

    CZF Magnetic Self-Priming Pump

    The CZF Magnetic Self-Priming Pump is a high-performance, leak-free pump designed for industrial, chemical, and municipal applications. Utilizing magnetic drive technology, the pump eliminates the need for conventional shaft seals, ensuring zero leakage and reduced maintenance requirements. Its self-priming capability allows it to handle low liquid levels, suction lifts, and challenging startup conditions, making it ideal for a wide range of fluid transfer operations.
  • Share:
  • Contact us Inquiry
  • WhatsApp:13852624478

Product Introduction

The CZF Magnetic Self-Priming Pump is a high-performance, leak-free pump designed for industrial, chemical, and municipal applications. Utilizing magnetic drive technology, the pump eliminates the need for conventional shaft seals, ensuring zero leakage and reduced maintenance requirements. Its self-priming capability allows it to handle low liquid levels, suction lifts, and challenging startup conditions, making it ideal for a wide range of fluid transfer operations.

The pump is constructed from high-quality stainless steel, fluorine-lined materials, or other corrosion-resistant alloys, depending on the chemical and temperature requirements. Its hermetically sealed magnetic drive prevents fluid leakage, providing a safe, environmentally friendly, and efficient pumping solution for hazardous, corrosive, or toxic liquids.

The CZF Magnetic Self-Priming Pump is widely applied in chemical processing, pharmaceutical manufacturing, food and beverage production, municipal water treatment, and industrial liquid handling systems. Optional features include variable frequency drive (VFD) compatibility, thermal protection, automatic priming systems, and PLC/SCADA integration, enhancing automation, precision, and reliability.

u=57838868,3410500920&fm=253&fmt=auto&app=138&f=JPEG.jpg

Key Features

  1. Magnetic Drive Technology

    • Eliminates conventional mechanical seals, preventing leakage.

    • Provides safe and environmentally friendly operation with hazardous or corrosive fluids.

  2. Self-Priming Capability

    • Capable of priming itself without external devices, handling low liquid levels efficiently.

    • Suitable for applications requiring intermittent or variable suction conditions.

  3. Robust and Corrosion-Resistant Construction

    • Pump casing and impeller made from stainless steel, fluorine-lined materials, or corrosion-resistant alloys.

    • Resistant to abrasion, corrosion, and chemical attack, extending service life.

  4. Wide Flow and Pressure Range

    • Flow rates: 1–1000 m3/h, depending on model and configuration.

    • Head: up to 80 meters, suitable for medium to high-pressure applications.

  5. VFD and Automation Ready

    • Compatible with variable frequency drives for precise flow control.

    • Supports PLC/SCADA integration for automated operations.

  6. Leak-Free Operation

    • Hermetically sealed magnetic drive eliminates the risk of leakage.

    • Ideal for toxic, flammable, or aggressive fluids.

  7. Thermal Protection

    • Integrated thermal sensors protect the pump motor from overheating.

    • Ensures safe continuous operation in high-temperature conditions.

  8. Low Maintenance

    • Minimal moving parts and no mechanical seals reduce maintenance requirements.

    • Modular design allows easy inspection and replacement of components.

  9. Versatile Applications

    • Chemical transfer, pharmaceutical liquids, food and beverage, municipal water, and industrial process fluids.


Technical Specifications (Product Parameters)

ParameterSpecification Range

Pump Type

Magnetic Self-Priming Pump

Flow Rate

1 – 1000 m3/h

Head

Up to 80 meters

Pressure

Up to 16 bar depending on configuration

Operating Temperature

-20°C to +120°C (varies by material)

Material of Construction

Stainless steel, fluorine-lined alloys, or other corrosion-resistant materials

Impeller Type

Closed or open magnetic drive impeller

Shaft Material

Stainless steel or corrosion-resistant alloy

Seal Type

Hermetically sealed magnetic drive

Motor Type

TEFC or submersible electric motor

Cable Type

Chemical-resistant, insulated, submersible or dry type

Drive Options

Electric motor, VFD compatible

Installation Type

Horizontal self-priming

Noise Level

<75 dB(A) depending on model


Applications of CZF Magnetic Self-Priming Pump

1. Chemical Industry

  • Transfers corrosive chemicals, acids, alkalis, and hazardous liquids.

  • Suitable for chemical tanks, process circulation, and chemical injection systems.

2. Pharmaceutical Industry

  • Handles pharmaceutical liquids, sterile solutions, and sensitive compounds.

  • Ideal for clean-in-place (CIP) systems and hygienic fluid transfer.

3. Food and Beverage Industry

  • Transfers viscous liquids, syrups, oils, and other food-grade materials.

  • Hermetic seal ensures contamination-free operation.

4. Municipal Water Treatment

  • Efficiently pumps water, wastewater, and reclaimed liquids.

  • Reduces leakage risks in municipal and industrial water systems.

5. Industrial Fluid Handling

  • Used in cooling water, process liquids, and chemical circulation.

  • Provides reliable flow, stable pressure, and leak-free operation.

6. Hazardous and Toxic Fluids

  • Safely transfers flammable, toxic, or environmentally sensitive liquids.

  • Hermetic magnetic seal prevents fluid escape and contamination.

7. Laboratory and Pilot Plants

  • Supports small-scale chemical, pharmaceutical, and food processing operations.

  • Easy to integrate with automation and monitoring systems.


Operating Instructions

Pre-Start Checks

  • Confirm pump installation, correct piping connections, and electrical setup.

  • Inspect magnetic coupling, impeller, and motor insulation.

  • Verify fluid compatibility with pump materials.

Start-Up Procedure

  1. Ensure pump and suction line are primed with fluid if required.

  2. Start motor at low voltage, gradually increase to operational voltage.

  3. Monitor flow rate, pressure, vibration, and temperature.

  4. Adjust VFD or control system to achieve desired flow and pressure.

Normal Operation

  • Operate within rated flow, pressure, and temperature limits.

  • Regularly check magnetic drive, vibration, and pump performance.

  • Inspect impellers and casing periodically for wear or damage.

Shutdown Procedure

  • Reduce flow gradually before stopping motor.

  • Disconnect power and drain fluid from pump if necessary.

  • Inspect and clean pump for storage or maintenance.


Maintenance Guidelines

  1. Routine Inspection

    • Monitor vibration, noise, and magnetic coupling alignment.

    • Inspect impeller, casing, and bearing surfaces regularly.

  2. Magnetic Coupling Maintenance

    • Check for wear, corrosion, or misalignment.

    • Replace worn or damaged components promptly.

  3. Motor Maintenance

    • Check insulation resistance, bearing temperature, and cooling.

    • Lubricate bearings as required for motor type.

  4. Seal Maintenance

    • Hermetically sealed magnetic drive requires minimal maintenance.

    • Inspect for wear or misalignment during scheduled checks.

  5. Cable and Electrical Maintenance

    • Inspect power cables and connectors for damage.

    • Ensure proper grounding and insulation integrity.

  6. Scheduled Overhaul

    • Recommended every 12–18 months depending on fluid and operation.

    • Inspect all internal components, replace damaged parts.


Common Problems and Solutions

ProblemPossible CauseSolution

Pump fails to prime

Air in suction line or low fluid

Check suction line, ensure proper fluid level

Flow rate below specification

Impeller blockage or wear

Clean or replace impeller

Excessive vibration or noise

Misalignment, bearing wear

Check alignment, replace bearings

Magnetic coupling slippage

Overload or misalignment

Adjust alignment, reduce load

Motor overheating

Overload, poor cooling

Check motor rating, ensure thermal protection works

Leakage

Rare, check magnetic drive seal

Inspect magnetic coupling and alignment

Corrosion or erosion

Fluid incompatibility

Verify material compatibility, clean pump


Advantages of CZF Magnetic Self-Priming Pump

  1. Leak-Free Operation – Eliminates mechanical seals, ensuring zero leakage.

  2. Self-Priming Capability – Handles low suction fluid levels and challenging startups.

  3. Corrosion and Chemical Resistance – High-quality materials resist harsh fluids.

  4. Energy-Efficient – Optimized impellers and hydraulic design reduce energy consumption.

  5. Automation Ready – Compatible with VFD and PLC/SCADA integration.

  6. Low Maintenance – Minimal moving parts reduce downtime and maintenance cost.

  7. Wide Application Range – Suitable for chemical, pharmaceutical, food, municipal, and industrial fluids.

  8. Certified Quality – ISO, CE, API certified for performance and reliability.


The CZF Magnetic Self-Priming Pump provides a safe, leak-free, efficient, and maintenance-friendly solution for industrial, chemical, pharmaceutical, municipal, and food-grade fluid handling. Its magnetic drive, self-priming capability, corrosion-resistant construction, and automation compatibility make it ideal for continuous, reliable, and environmentally safe fluid transfer operations.

ONLINE MESSAGE

Please fill in a valid email address
Captcha Can not be empty

RELATED PRODUCTS

No search results found!

This website uses cookies to ensure you get the best experience on our website.

Accept Reject
滨海县| 文水县| 房产| 和平县| 南平市| 永寿县| 庆阳市| 乐至县| 皮山县| 南城县| 中宁县| 砚山县| 道孚县| 额济纳旗| 宣化县| 塘沽区| 连城县| 太和县| 贵州省| 清流县| 湛江市| 合作市| 海原县| 板桥市| 田阳县| 遵义市| 修武县| 万源市| 望谟县| 五寨县| 清镇市| 阳高县| 华安县| 株洲市| 象州县| 黄浦区| 大埔县| 遵义市| 乌拉特前旗| 墨脱县| 稷山县|